HVX. Vacuum circuit-breaker up to 36 kV. Medium-Voltage Switching Devices. HVX. HV. HVX. 0. MEDIUM-VOLTAGE SWITCHING DEVICES. AREVA T&D. HVX Assembled Pole – Indoor MV Vacuum Circuit Breaker up to 24 kV. The HVX series circuit-breakers are vacuum circuit-breakers for application in 12 to 24 kV indoor switchgear units. Operating conditions. The circuit-breakers.

Author: Kagalkis Voshicage
Country: France
Language: English (Spanish)
Genre: Technology
Published (Last): 23 December 2012
Pages: 440
PDF File Size: 8.17 Mb
ePub File Size: 17.45 Mb
ISBN: 478-1-13429-250-7
Downloads: 5550
Price: Free* [*Free Regsitration Required]
Uploader: Zulkijin

For the design and method of operation of ageva transport truck used, please refer to the instructions for the panel in question.

If voltage is applied to the motor, charging is performed automatically.

In case of AC voltage, the coil is supplied via a rectifier installed in the switch housing. If additional control lines xreva placed in the drive hv, leave a sufficient distance from the movable parts of the drive. The energy storing device can be charged immediately after switching ON by hand or by motor.

Browse services Field Services Optimize hv life adeva of your assets, improve performance, safety, and reduce maintenance costs — all with an experienced provider of complete field services and a partner you can trust. Appropriate interlocks rule out faulty switching operations. The energy for a complete switching cycle can be stored in the spiral spring. Auxiliary opening release option Auxiliary closing release Indirect overcurrent release option Undervoltage release option Anti-pumping-relay Units incorporated in the switchgear truck in compliance with order Test position switch Service position switch Blocking magnet blocking for trolley option Drawing number: Next, discover our energy and sustainability services, including big data management, to turn this vision into your business reality.

Energy Transformations Energy cannot be created or destroyed. Depending on the order volume, components shown may not be included. Bolts and socket-head cap screws except slotted screws and nuts except selflocking nuts Table 2: It enables the Panel Builder to design switchgear solutions with fixed type or withdrawable type of circuit breaker with enhanced safety features, full control from a separate areav and with the following technical characteristics:.

  FVT-4001 MEDIA CONVERTER PDF

Reliability, operator safety and the mechanical functions of the switching devices have been proved in endurance tests or under regular operating conditions. The switching functions have been set in the factory according to the wiring diagram.

It is characterized by compact dimensions, good operator guidance and a modern functional industrial design. Any damage to the paint, scratches and other damage must be repaired immediately to avoid corrosion.

Make sure the rope or strap is strong enough to bear the weight of the circuit- breaker and do not touch the circuit-breaker. Schneider Electric Energy Efficiency Management Platform With its deep understanding of the five markets, the careful care of corporate clients, as well as in the field of energy management experience, Schneider Electric from a good supplier of products and equipment have grown to a total solution provider.

Remove the withdrawable unit from the switchgear cubicle for inspection see instructions for the panel concerned. The use of other auxiliary products is not admissible.

Operation under conditions deviating from these is only admissible upon consultation and with the written approval of the manufacturer. The rated current A is guarantied with force cooling in panel Rated current Rated short clrclut current 25 It remains in this initial position until the ON command arevva issued anew.

Schneider Electric to help you – make the best use of its efficiency, enjoy the energy! If necessary, clean see Chapter 8. Secondary release Transformer-operated release Secondary releases are used for automatic release of switching ateva in case of short-circuits and overcurrent.

Areva breakers type HVX for DeWind D | Spares in Motion

Ambient temperatures Temperature class: Remove the lifting brackets before entering in cubicle. All dimensions not specified in detail are in millimeters. Do not perform any work on the circuit-breaker which is not described in this Technical Instruction.

It must be stored so that it is at any time readily accessible for and can be used by persons who are to work on the switchgear. These rules apply for the upper and lower circuit-breaker terminals alike. Comply with safety Provisions Chapter 1. Undervoltage release Undervoltage releases are supplied by the auxiliary source permanently. Auxiliary opening release F12 2. It may only be used in the scope of the specified standards and the switchgear-specific technical data.

  DANIELLE STEEL UNA PERFETTA SCONOSCIUTA PDF

HVX 12-17.5-24(technical instruction)

They warn about dangers or provide important information which must be complied with at all costs so as to avoid danger and damage: Auxiliary opening release 2. A rope with a diameter of 12 to 15 mm or a strap is required.

Contact the manufacturer’s Service Center. It enables the Panel Builder to design switchgear solutions with fixed type or withdrawable type of circuit breaker with enhanced safety features, full control from a separate room and with the following technical characteristics: Schneider Electric’s strong support for the high investment in China’s economic construction and to provide Chinese customers with advanced technical and product support and improve Technical services, the low-voltage electrical appliances, converter, contacts and other industrial products, extensive use of economic construction in China, promoting China’s industrial Of the process.

Any other use constitutes improper use and may result in dangers and damage. Connection to terminal strip Remove the cover plate.

The use of other cleaning agents is not admissible. Connect external control lines via the terminal strip. Gas-insulated switchgear type 8DQ1, kV, 80 kA siemens. Insert crank into opening for tensioning the energy storing device Fig.

Areva breakers type HVX-24-25-06 for DeWind D8.2

Spring-charging mechanism of the drive using a arsva Approx. By working with partners and the cooperation of a large number of dealers, Schneider Electric China has created tens of thousands of jobs. Pulsing can be initiated by hand, via control switches, overcurrent releases or undervoltage releases.

On principle, general cleanliness of the circuit-breaker or of its external parts should be ensured. Operating reliability and service life depend on correct operation.