HIOKI 3280 PDF

H H. F. F. EN. Device may be connected to or disconnected from a live conductor. Flexible sensors can be connected to or. Hioki is pleased to announce the launch of the AC Clamp Meter F ( featuring true RMS measurement) and the AC Clamp Meter Set. Hioki Clamp On HiTester. Discontinued See: F. Easy Operation ; A rms, clamp aperture: 33 mm (“) diameter; Light – g ( oz).

Author: Viramar Sataxe
Country: Panama
Language: English (Spanish)
Genre: Software
Published (Last): 12 July 2011
Pages: 314
PDF File Size: 3.10 Mb
ePub File Size: 4.20 Mb
ISBN: 550-7-30995-685-3
Downloads: 50315
Price: Free* [*Free Regsitration Required]
Uploader: Fell

The F performs true RMS AC measurement, enabling it to accurately measure waveforms that are distorted due to use of inverter-equipped devices or switching power supplies. Cable length mm Observe the difference between readings from these two types of instruments hiokii measuring a distorted waveform that contains harmonic components such as those produced by inverters and switching power supplies.

Both methods can accurately measure current that takes the form of hoiki distortion-free sine wave, but the mean-value method is incapable of accurate measurement when the waveform is distorted due to use of inverter-equipped devices or switching power supplies.

Hioki and Clamp On HiTesters, Hioki – at the Test Equipment Depot

As a result, it is becoming difficult to make measurements even with the low-profile jaws as hloki clamp-on sensor portion of the instrument is known that have been a feature of previous products. Seminar Schedule No results were found.

Measurements taken with the Hioki F which uses the mean value method and the the Hioki F which uses the true RMS method are compared. Since the F supports true RMS measurement, it can accurately measure current even when the waveform is distorted. Log into your myHioki account to access more technical documents and information where available.

Operation under a broader array of conditions thanks to an expanded operating temperature range The F features an expanded operating temperature range.

True RMS measurement to enable accurate measurement of currents, even when the waveform is distorted There are two methods for measuring AC currents: Seminar Videos On Demand No results were found. Drivers, Firmware No results were found. When connected to an optional flexible current sensor, the F can be used to measure the current flowing in pairs of wires or in tangled or complexly routed wires around which it was not possible to apply a clamp-on sensor in the past.

  BIRKHOFF MACLANE ALGEBRA MODERNA PDF

By offering over main products characterized by safety andquality while meeting an expansive range of applications, we aim to contribute to the efficiency and value of our customers’ work in research and development, production and electrical maintenance. Technicians maintaining electrical equipment in buildings and manufacturing plants need to measure current and voltage.

Usable temperature range Max. However, if the signal being measured is distorted, mean value rectification introduces an error component, whereas true RMS measurement yields an accurate RMS value. For more information, please contact: HIOKI products and services are available around the world through our extensive network of subsidiaries and distributors.

For many years, Hioki has supplied clamp-on current meters used in the field to carry out such electrical work. In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality.

AC CLAMP METER

Gallery No results were found. A pocket clamp meter that can use flexible sensors When connected to an optional flexible current sensor, the F can be used to measure the current flowing in pairs of wires or in tangled or complexly routed wires around which it was not possible to apply a clamp-on sensor in the past.

Furthermore, the CT can be used to measure large currents of up to A. A thin card tester that fits in the pocket with all the capabilities of a clamp meter The F delivers all the functionality of a clamp meter and card tester in the form factor of the latter. The F delivers all the functionality of a clamp meter and card tester in the form factor of the latter. As a result, it is becoming difficult to measure wires with the low-profile, jaw-type clamp clamp-on current sensor typically used in previous products.

Maintenance and management of electrical equipment in buildings and at manufacturing plants necessitates current and voltage measurement, and Hioki has long supplied clamp-on meters for use in the field by electrical professionals.

Introduction to functionality and measurement methods In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality. Difference between mean value and true RMS measurement Measurements taken with the Hioki F which uses the mean value method and the the Hioki F which uses the true RMS method are compared.

  ADAC PANNENSTATISTIK 2005 PDF

Providing the finest test equipment solutions since 1992

Their compact size, low-profile design, and resistance to both rough handling and extreme temperatures make them essential tools for any electrician. The F and F enhance yioki previous and with a broader range of operating temperatures along with the addition of the CT as an option, making measurement more convenient for customers.

HIOKI products and services are available around the world through our extensive network of subsidiaries and distributors. Furthermore, the CT can measure large currents of up to A.

Easy measurement of tangled wires when used with a flexible current sensor As distribution panels have become smaller in recent years, technicians have increasingly found themselves faced with tangled wiring.

For more information, please contact: Basic specifications Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year Hikki Current As a result, it can be used in even harsher environments.

By offering over main products characterized by safety and quality while meeting an expansive range of applications, we aim to contribute to the efficiency and value of our customers’ work in research and hiiki, production and electrical maintenance. In addition to current measurement, this single instrument delivers voltage measurement, continuity check, and resistance measurement functionality. User Guides No results were found. CT Basic specifications Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year Core jaw dia.

Using series AC clamp meters: Technical Notes No results were found.

Essential for electrical work: A clamp meter with true RMS measurement capability is required in order to accurately measure current under such conditions.

Ability to make measurements in confined locations easily with a flexible current sensor As distribution panels have become hoki in recent years, the density of the wiring they contain has increased.