There are three distinct test method in ISO the neutral salt spray (NSS), the acetic acid salt spray (AASS), and copper-accelerated acetic. ISO NSS. adv. auto technology banner. A discussion started in but continuing through Q. We have a customer, that we supply some zinc. The salt spray (or salt fog) test is a standardized and popular corrosion test method, used to Other important relevant standards are ISO, JIS Z and ASTM G The most common test for steel based materials is the Neutral Salt Spray test (often abbreviated to NSS) which reflects the fact that this type of test.

Author: Kerisar Zuluzil
Country: Croatia
Language: English (Spanish)
Genre: Politics
Published (Last): 13 July 2004
Pages: 394
PDF File Size: 12.40 Mb
ePub File Size: 6.91 Mb
ISBN: 138-3-91389-568-2
Downloads: 73618
Price: Free* [*Free Regsitration Required]
Uploader: Kesida

The longer the accelerated corrosion test, the longer the process remains out of control, and larger is the loss in the form of non-conforming batches. It also describes the method employed to evaluate the corrosivity of the test cabinet environment. You will then need to talk to your customer about the possibility of using one specification in lieu of the other. ASTM G85 is the most popular global test standard covering modified salt spray tests.

This is followed by 1. The test duration is variable. Test specimens are placed in an enclosed chamber, and exposed to 1 nxs 2 possible changing climate cycles. It’s not possible to diagnose a finishing problem or the hazards of an operation via these pages.

Website design by Peter Bourne Communications. This climate is maintained under constant steady state conditions. What is major difference between ISO [link by ed.

The first climate cycle comprises a continuous indirect spray of iao pH 6. This spray is set to fall-out on sns the specimens at a rate of 1. Hot-dip galvanizing produces zinc carbonates bss exposed to a natural environment, thus protecting the coating metal and reducing the corrosion rate. Such details are nxs in the appropriate product specifications.

This website has been developed with modern browsers in mind to allow it to display at its best in a wide variety of viewing situations – including mobile viewing. ISO gives the guidelines for proper measurement of corrosion resistance for hot-dip galvanized specimens.

  HP OFFICEJET 9130 MANUAL PDF

For example, izo typical electroplated zinc and yellow passivated steel part lasts 96 hours in salt spray test without white rust.

Salt spray testing is popular because it is relatively inexpensive, quick, well standardized, and reasonably repeatable. The principle application of the salt spray test is therefore enabling quick comparisons to be made between actual and expected corrosion resistance.

ISO standards by standard number. In either case, the exposure to salt spray may be salt water spray or synthetic sea water prepared in accordance with the requirements of the test standard. Hi David, There are several differences between the two specifications, including salt concentration range, salt analysis, water quality, 92277 of inclination of test panels, corrosivity requirements, I think the temperature is about the only thing that has been standardised.

Is there any equivalence between this two standards? Requirements are agreed between customer and manufacturer.

But benchmarking performance is something 9227 different. It has also been found suitable for testing anodic and organic coatings on aluminium. George Gorecki – Naperville, Illinois A.

A personal good afternoon to all, I am Jose of Curitiba, I am a painting inspector, I am a specialist in the area of Salt Spray, and have a problem and knowing of the competence of all readers in corrosion, perhaps they can help me. Painted surfaces with an underlying hot-dip galvanized coating can be tested according to this method. So if you want to 92277 how to set up a salt spray cabinet or how to make the salt solution, then B is a reference.

Most Salt Spray Chambers today are being used NOT to predict the corrosion resistance of a coating, but to maintain coating processes such as pre-treatment and painting, electroplating, galvanizing, and the like, on a comparative basis.

Equivalence between ASTM B vs. ISO NSS

The test duration is variable. Corrosion tests and standards: Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 2 part repeating cycle. This page was last edited on 29 Octoberat Hi Sergio, ASTM B does not address corrosion behavior of test specimens, but describes the parameters for conducting a salt spray test.

  KLAVIERSTCK XI STOCKHAUSEN PDF

Cyclic corrosion testing is better suited to this.

nws We did tests of our products under ISO Synthetic seawater solutions are also commonly specified by some companies and standards. Chamber volumes vary from supplier to supplier. Monday to Friday – Salt spray testing is an accelerated corrosion test that produces a corrosive attack to coated samples in order to evaluate mostly comparatively the suitability of the coating for use as a protective finish. Toby Padfield – Troy, Michigan.

Corrosion tests in artificial atmospheres – Salt spray tests

Daily checking of testing parameters is necessary to show compliance with the standards, so bss shall be maintained accordingly. This acceleration arises through the use of chemically altered ixo spray solutions, often combined with other test climates and in most cases, the relatively rapid cycling of these test climates over time.

Something totally different like zinc-alloy plating, organic coatings, etc. A discussion started in io continuing through Q. These collectors are located inside the chamber, nominally at the same height as the test samples, one located close to the atomiser and one located away from the atomiser, in accordance with the positions specified in ASTM B, but also taking into account the chamber manufacturers defined work-space.

This is followed by 2. Remember that accelerated testing is not a proper indication of real world performance. Both are excellent browsers.

These standards describe the necessary information 922 carry out this test; testing parameters such as temperature, air pressure of the sprayed solution, preparation of the spraying solution, concentration, pHetc. Retrieved from ” https: Different coatings have different behavior in salt spray test and consequently, test duration will differ from one type of coating to another.

May 21, A. Testing cabinets are manufactured according to the specified requirements here.